Preface | p. xiii |
General Considerations in Quality Management in Brachytherapy | p. 1 |
Importance of quality assurance | p. 1 |
Principles of quality assurance | p. 2 |
Error | p. 8 |
Systematic error | p. 8 |
Random error | p. 8 |
Error reduction | p. 8 |
Error prevention | p. 8 |
Error detection | p. 11 |
Guidance in the use of tools | p. 12 |
Training | p. 13 |
Staffing | p. 16 |
Items not covered | p. 18 |
Terminology revisited | p. 19 |
Sources for information | p. 19 |
Human performance implications for quality management | p. 20 |
Summary | p. 20 |
Quality Management for Manual Loading, Low Dose Rate Brachytherapy Sources | p. 21 |
Sources for a permanent inventory | p. 21 |
Acceptance tests | p. 21 |
Periodic tests | p. 33 |
Sources ordered for particular patients | p. 36 |
Integrity | p. 37 |
Linear uniformity--wire (not seeds, which are too short to matter) | p. 37 |
Assay of source strength | p. 37 |
Penetration and dose distribution | p. 40 |
Summary | p. 41 |
Quality Management for a Treatment Plan | p. 42 |
Evaluating whether the plan contains errors | p. 42 |
Direct checks on the input data | p. 42 |
Does the plan make sense? | p. 52 |
Indirect checks on the input data | p. 53 |
Evaluating the appropriateness of the plan | p. 54 |
Concerns in evaluating the appropriateness of a treatment plan | p. 55 |
Tools | p. 59 |
Summary | p. 76 |
Quality Management for Manually Loaded, Low Dose Rate Applications | p. 78 |
Applications involving sources from a standing inventory | p. 78 |
Source loading | p. 78 |
Calculation of the removal time | p. 80 |
During the treatment | p. 81 |
At the removal | p. 82 |
Applications involving temporary sources ordered for the treatment | p. 82 |
Source loading | p. 82 |
Calculation of the removal time | p. 86 |
During the treatment | p. 87 |
At the removal | p. 88 |
Applications involving sources ordered for a permanent implant | p. 88 |
Source strength check | p. 88 |
Source position checks | p. 89 |
Implants using radium or caesium needles | p. 94 |
Summary | p. 95 |
Quality Management for High Dose Rate Units | p. 97 |
Periodic evaluations (at the beginning of each treatment day) | p. 98 |
Safety checks | p. 99 |
Dosimetry checks | p. 101 |
Initial checks | p. 114 |
Safety checks | p. 114 |
Dosimetry checks | p. 115 |
Ancillary device checks | p. 117 |
Acceptance testing and commissioning | p. 119 |
Operation | p. 119 |
Detection of obstructions | p. 119 |
Source retraction--automatic (emergency) | p. 120 |
Source retraction--manual | p. 120 |
Loss of source | p. 120 |
Checks during treatment | p. 120 |
Checks after treatment | p. 121 |
Summary | p. 121 |
Pulsed dose rate units | p. 122 |
Quality Management for High Dose Rate Treatment Plans | p. 126 |
Error prevention | p. 127 |
Protocols | p. 128 |
Forms | p. 128 |
Independent second person | p. 128 |
Error detection | p. 128 |
Independent physicist's review | p. 129 |
Physician's review | p. 144 |
Predelivery checks | p. 145 |
Indicators of 'reasonableness' | p. 147 |
Gynaecological intracavitary insertions | p. 147 |
Intraluminal insertions | p. 150 |
Interstitial implants | p. 152 |
When the checks fail | p. 155 |
Summary | p. 157 |
Some recommendations from the report of Task Group 59 of the American Association of Physicists in Medicine | p. 158 |
Quality Management for Low and Medium Dose Rate Remote Afterloaders | p. 161 |
Advanced remote afterloaders | p. 162 |
Checks per patient | p. 163 |
Periodic checks | p. 166 |
Basic remote afterloaders | p. 168 |
Checks per patient | p. 170 |
Periodic checks | p. 171 |
Procedural quality considerations with basic remote afterloaders | p. 174 |
Reported operational problems with LDR remote afterloaders | p. 175 |
Simple source loaders | p. 176 |
Dose rate considerations | p. 176 |
Summary | p. 178 |
Quality Management for Brachytherapy Appliances | p. 179 |
Intracavitary applicators | p. 179 |
Gynaecological appliances | p. 180 |
Intraluminal applicators | p. 192 |
Interstitial equipment | p. 193 |
Source-holding needles | p. 193 |
Catheters | p. 196 |
Flexible needles and fixed-length plastic tubes | p. 200 |
Templates | p. 200 |
Surface applicators | p. 204 |
Eye applicators | p. 205 |
Skin applicators | p. 206 |
Intraoperative applicators | p. 207 |
Summary | p. 207 |
Quality Management for Dosimetric Treatment Planning | p. 210 |
Localization | p. 211 |
Radiographic localization | p. 212 |
Sectional localization | p. 218 |
Ultrasound localization | p. 221 |
Source simulation | p. 222 |
Dose calculation | p. 225 |
Digitization | p. 227 |
Geometric reconstruction | p. 228 |
Dose calculation | p. 228 |
Plan output | p. 235 |
Summary | p. 237 |
Appendix 9A | p. 237 |
References | p. 240 |
Index | p. 247 |